Example: Bible, Android

  • PDF
  • DOC
  • XLS
  • RTF
  • TXT
  • PPT

Ul u366 PDF results

Proroc™ shaftliner for area separation walls

Separation area walls ul design u366 ral tl100-176 for stc ratings for further technical information regarding sound control and fire resistance refer to the following: gypsum association fire resistance design manual - ga-600 area separation walls... Separation area walls ul design u366 ral tl100-176 for stc ratings for further technical information regarding sound control and fire resistance refer to the...

Bxuv.u366 - fire resistance ratings - ansi/ul 263

... installation and use of ul listed or classified products, equipment, system, devices, and materials.* authorities having jurisdiction should be consulted before construction.* fire resistance assemblies and products are developed by the design... Design/system/constructio n/assembly usage disclaimer * authorities having jurisdiction should be consulted in all cases as to the particular requirements...

Product data and submittal

Certainteed job name contractor date products specified: submittal approvals(stamps or signatures) continued on back product data and submittal moisture and mold resistant shaftliner type x with m2tech tm gypsum board product description proroc® shaftliner with m2tech tm isa 1" (25.4 mm) thick gypsum board with aspecially formulated fire resistive... Area separation firewalls astm c 1396, c 475, c 645, c 754, c840, c 1002, c 1047, e 84, e 119; can/ulc-s101, can/ulc-s102, can/csa-a82.27, ga-600, ga-216, ga-238; ul u366...

System no. w-l-5259

System no. w-l-5259 wl 5259 page: 1 of 2 1. wall assembly - the 2 hr fire-rated gypsum board, wood stud wall assembly shall be constructed of the materials and in the manner described in design no. u336 or u366 in the ul fire resistance directory and shall include the following construction features: a. studs - 1. area separation wall framing... ... the 2 hr fire-rated gypsum board, wood stud wall assembly shall be constructed of the materials and in the manner described in design no. u336 or u366 in the ul...

Submittal approvals (stamps or signatures)

Job name contractor date products specified: submittal approvals (stamps or signatures) continued on back product data and submittal product description glasroc ® shaftliner type x for use in shaftwall and area separation firewall systems is a 1" (25.4 mm) thick gypsum board with a specially formulated fire Ga-238; ul u366, ulc w311. recommendations installation of glasroc ® shaftliner boards should be consistent with methods described in the standards and...

Product data and submittal

Area separation walls astm c 1396, c 442, c 475, c 645, c 754, c 840, c 1002, c 1047, e 84, e 119; ga-600, ga-216; ul design u366. recommendations...

Ordinance no. 06-o-64

2006 irc - residential code - 11-15-06 ordinance no. 06-o-64 ordinance adopting the international residential code, 2006 edition, subject to specified amendments an ordinance of the village of round lake adopting the 2006 edition of the international residential code, regulating and governing the construction, alteration, movement, enlargement... Fire separation walls shall be a minimum of ul u366 or equivalent. r317.2 delete exception to this section. r319.1.3 delete the paragraph and insert the following:...

Certified projects in canada steel bridge case study the rom ...

Advantage steel thermal mass research exploring leed certified projects in canada steel bridge case study the rom: merging steel and technology steel frames healthcare what's cool, what's hot, what's new canadian institute of steel construction no 26 summer 2006 ul is design u366. literature of bpb illustrates the system (i do have a pdf file of this illustration if you are interested). i have had this inquiry before and was in...

Top Queries


Recent Searches

 
DOC-TXT