Example: Bible, Android

  • PDF
  • DOC
  • XLS
  • RTF
  • TXT
  • PPT

Fire pumps 1000 gpm PDF results

World-class fire suppression pumping solutions

Standing guard for the safety of millions from europe to australia, south america to the far east, commercial, residential and industrial facilities around the globe are depending on patterson fire suppression pumps and pre-pac® engineered self-contained systems. millions count on patterson for their unparalleled knowledge and expertise in... ... to 1,000 gpm (3,785 litres/min) and heads to 1,150 ft (351 m). high pressure two-stage dmd fire pumps engineered... end suction fire pumps are available in flow ranges of 50 gpm...

1000 gpm fire pumps

Min.min. dia.dia. no. ofno. of vanesvanes 0 200 400 600 800 1000 1200 1400 1600 1800 175total head in psi flow in gpm bhp 1000 gpm fire pump approval pressure range 124-156 ul & fm1000 gpm fire pump approval pressure range 124... Curvecurve pumppump speedspeed rpmrpm imp.imp. no.no. max.max. dia.dia. max.max. spheresphere impeller dataimpeller data inletinlet areaarea

pumps for marine applications

Hale products manufactures superior engine driven pumping units for a variety of fire and marine applications. some units are available with bronze, iron, or anodized construction to meet the need for corrosion resistance in salt or brackish water. hale's marine pumping units combine efficient performance with pump capability ranges to meet a... Hale has over 90 years of experience in manufacturing the best performing fire pumps... up to 750 and 1000 gpm. rsd-m compact pump available in engine or...

fire pumps

Horizontal split case fire pump system diesel engine driven 1 2 3 4 5 6 7 8 pump: horizontal split case, double-suction, ul listed, fm approved, mounted on a common base with and flexibly coupled to a diesel engine. pump sized for rated capacity and head. also must be capable of producing 150% rated flow at not less than 65% rated head and not to... ... system to prevent the main fire pump from operating to maintain system pressure. jockey pumps are generally a few gallons per minute... 370 psi 750 gpm 99 - 361 psi 1000 gpm...

Application data - fire pump

Introduction armstrong darling fire pumps meet all of the requirements for fire pump service with its standard production pumps. armstrong darling fire pumps are constructed in accordance with the requirements of underwriter's laboratories of canada (ulc), underwriters' laboratories inc. (ul), factory mutual research corporation (fm) and comply... Types of fire pumps − horizontal split case pumps − horizontal split... example: for 1000 gpm at 110 psi select a 6x5x10f fire pump with a 100 hp <^et^>...

Specifications - vehicle mounted: model cm 500, 750, 1000, 1250 gpm

2010 waterous company 125 hardman avenue south, south st. paul, minnesota 55075-2456 usa f-1194 www.waterousco.com specifications subject to change without notice. rev: 10/09/11 specifications - vehicle mounted: model cm 500, 750, 1000, 1250 gpm the results of waterous' advanced engineering capabilities are quality products that are Rev: 10/09/11 specifications - vehicle mounted: model cm 500, 750, 1000, 1250 gpm the... design features have enabled us to continue providing the most reliable fire pumps...

South dakota division

Multi-stage fire pumps nh series fire pump specifications nh 500 gpm at 150 psi, nh 750 gpm at 150 psi, nh 1000 gpm at 150 psi, nh 1250 gpm at 150 psi. meets full nfpa rating. all models also produce 100 gpm at 600 psi simultaneously from the high pressure stage. design: multi-stage high pressure/volume fire pump. Rosenbauer 500, 750, 1000 and 1250 gpm. multi-stage fire pumps nh series fire pump specifications. pump ratings: nh 500 gpm at 150 psi, nh 750 gpm at 150 psi, nh 1000 gpm...

pump school manual

table of contents chapter 1 characteristics of water … page 3 pressures, atmospheric, static, residual, head … page 7 chapter 2 pump construction and gauges … page 10 chapter 3 friction loss … ... 1,000 gallons per minute at a large fire... pumps come in several capacities: 500 gpm, 750 gpm, 1,000 gpm, 1,250 gpm, 1,500 gpm, and 2,000 gpm. the most common type of fire...

Nfpa 1901 standard for automotive fire apparatus

Tentative interim amendment nfpa 1901 standard for automotive fire apparatus 2009 edition reference: various sections tia 09-1(sc 08-10-8/tia log #934) pursuant to section 5 of the nfpa regulations governing committee projects, the national fire protection association has issued the following tentative interim amendment to nfpa 1901, standard for... ... shall certify that the fire pump is capable of pumping 100 percent of rated capacity at 150 psi (1000 kpa) net pump pressure for pumps rated at less than 3000 gpm...

Types of fire pumps

Design and pump application, review basic fire pump room design, and review nfpa 20 including new changes in 2003 along with existing code information. 3 types of fire pumps types of fire pumps split case fire pumps inline fire pumps vertical turbine fire pumps 2 4 split case fire pump split case fire pump models models 5 removable... 1 fire pumps 101 fire pumps 101 2 purpose purpose • this session will cover basic... 2000 gpm 50 gpm 450 gpm 2500 gpm 100 gpm 500 gpm 3000 gpm 150 gpm 750 gpm 3500 gpm 200 gpm 1000 gpm...

Peerless pump

Full product line full product line product type description capacities head horsepower temperature request brochure vertical industrial and process pumps vertical close coupled single stage or multi-stage turbine pumps up to 150,000 gpm(34,091 m3/hr) up to 2,300 feet(701 meters) up to 5,000 hp(3,730 kw) up to 450 f (232 c) b-110 axial and mixed... Up to 8,000 gpm (1,818 m3/hr) up to 1,000 feet (305 meters) up to 500 hp (373 kw) ambient within... to 95 meters) up to 60 hp (45 kw) up to 180 f (82 c) b-9200 vertical fire pumps...

World class fire pumps

Patterson pump company continues to be the industry leader in prompt delivery of fire pumps worldwide, providing horizontal split case, vertical turbine, end suction and vertical in-line pumps, with electrical motors, diesel engines or dual drive combinations. its fire protection pumps were shipped to over 60 countries in the year 2000. All patterson fire pumps conform to, and in most cases surpass, the... pressures of 40 to 390 psi and capacities of 150 to 5,000 gpm. vertical in-line and end suction pumps...

fire suppression work: the guide to fire pump installation and testing

fire pumps at a glance installation of a fire pump is governed by section 27-946 of the city's administrative code. it requires that "additional water supply be provided for standpipes in buildings over 300 feet high by one or more manually-operated fire pumps."when a fire pump is required to be installed, the pump must be tested and pass... A minimum of 3-inch test pipe is required for 500 gpm pumps and 4 inch for 750 gpm pumps. • manual fire pump control: the first step of the starter shall...

fire pumps - ul listed / fm approved fire pumps horizontal split ...

Naffco's new range of ul standard fire pumps provides you a reliable solution for your fire fighting pump needs by combining the stringent quality measures of ul and nfpa standards with our proven experience in the fire protection field. we can offer you a complete package of service starting from engineering assistance to field start-up and... fire pumps. ul listed / fm approved fire pumps horizontal split case... per nfpa and ul standards. horizontal split casing pumps for capacities of 750 us gpm and 1000...

Application for license to authorize near-surface land disposal of ...

Application for license to authorize near-surface land disposal of low-level radioactive waste appendix 3.0-3: wcs llrw disposal calculations march 16, 2007 3.0-3.36-1 revision 12a attachment 3.0-3.36: fire main and pump sizing calculation summary urs calculation: wcs-004-nc-019, fire line objective: • the selected fire pump is specified as capacity 1,000 gpm under pressure 100 psi. • pump operation capacities, q gpm vs. available water head, ha (psi) are...

Big flow systems

Big flow systems an integrated mobile high capacity foam and water delivery solution. use as a comprehensive system or as individual components to enhance existing equipment. major innovations in fire fighting and water transfer technology big flow systems big flow systems from national foam, angus flexible pipelines, and kidde fire fighting... Whether it be an oil refinery storage tank fire; a critical water main... neptune employs two (2) portable, floating, 2,500 gpm, satellite pumps (255 lbs. each) that...

Marine pumping units

Hale products manufactures superior engine driven pumping units for a variety of fire and marine applications. some units are available with bronze, iron, or anodized construction to meet the need for corrosion resistance in salt or brackish water. hale's marine pumping units combine efficient performance with pump capability ranges to meet a... Hale has over 90 years of experience in manufacturing the best performing fire pumps... up to 750 and 1000 gpm. rsd-m compact pump available in engine or...

fire apparatus pump test

Training bulletin topic: fire apparatus pump test effective date: 05/06 doc no: tb081 cross ref: author: bert byers, battalion chief page 1 of 12 reviewed: craig bowen, fire chief approved: craig bowen, fire chief origin date: 05/95 revised date: 01/96, 04/06 introduction district fire apparatus pump testing is completed on an annual basis. Training bulletin topic: fire apparatus pump test effective date: 05/06 doc no... time test ends when water discharges at nozzle and out of priming pump) 1000 and 1250 gpm pumps...

A1 transportable pumps goulds/caterpillar 6,000 gpm description ...

The dependapower dpgou 6040 cat-r is a trailer mounted, diesel driven horizontal split case centrifugal fire water pumping system. nominal performance rating is 6,000 gpm {++@++} 150 psi net (10' lift). designed to be moved from one location to another without having to realign the pump coupling. entire assembly is built on a skid base which also... ... horizontal split case centrifugal fire... indicated a flow rate of 8,326 gpm at the monitors at 125 psi. adaptations: pumps are... 100 at 1000 rpm

Top Queries


Recent Searches

 
DOC-TXT