Example: Bible, Android

  • PDF
  • DOC
  • XLS
  • RTF
  • TXT
  • PPT

Central sprinklers model a PDF results

central omega sprinklers

City of bellevue october 2006 central omega sprinklers city of bellevue • fire prevention division • 425-452-6872 public information handout f-13 the following information is to alert you to a potential defect in a particular model of sprinklers that may be installed in your building. the bellevue fire department, in cooperation with... City of bellevue october 2006 central omega sprinklers city of bellevue • fire prevention division... or replacement of the omega model sprinklers...

Identification brochure for "central" commercial wet sprinklers

- introduction to the "voluntary replacement program" this brochure provides information that will assist you in identifying whether the sprinklers in your sprinkler system are the o-ring sprinklers involved in this voluntary replacement program ("vrp" or "program"). in addition, this brochure contains information that you will need to accurately... It is important to properly identify the model(s) of sprinklers installed in a... - 7 - table a - "central" commercial sprinklers sprinkler may contain...

central recall #2

Issued: 07-25-01 california state fire marshal information bulletin central sprinkler recall the consumer products safety commission (cpsc) and central sprinkler company have announced the recall of the company's sprinkler heads with rubber o-ring seals. a list of specific models included on page 4 of this bulletin. the state fire marshal has... The model designation and... gb-lo bb2 17/32 hip elo-231 gb gb multi-level gbr-2 lf bb3 17/32 ws elo-gb gb-qr multi-level gb-ec gbr bb1 elo-lh elo-23 gbqr elo-16 gbfr central dry sprinklers...

central sprinkler company

Always refer to central sprinkler's product data sheets for central's warranty information and design information prior to using or installing any products. 3 central's standard response spray sprinklers are used in fire sprinkler systems designed in accordance with the installation rules recognized by the applicable listing or approval agency. The central sprinklers that are available for... td# 5-6.5 elo-231 td# 5-11.0 elo-16 ecoh td# 5-13.0 csc quick response dry sprinklers specifications model...

Modelh (sinr 5012) early suppression fast response sprinkler

Modelh (sinr 5012) early suppression fast response sprinkler product description the reliablemodel hearly suppression fast response (esfr) sprinkler is intended for use against severe fire challenges. this sprinkler is designed to respond quickly to growing fires and will delivera heavy water discharge to"suppress"rat her than"control"fi res. the... ... of suppressing fires between sprinklers in high storage height areas and a t the same time retaining a hig h momentum central... model hesfrsprinkler... new sprinklers...

Identification brochure for wet and dry o-ring sprinklers

- introduction to the "voluntary replacement program" this brochure provides information that will assist you in identifying whether the sprinklers in your sprinkler system are the o-ring sprinklers involved in this voluntary replacement program ("vrp" or "program"). in addition, this brochure contains information that you will need to accurately... It is important to properly identify the model(s) of sprinklers installed in a... - 7 - table a - "central" commercial sprinklers sprinkler may contain...

Fire protection technical advance

central sprinkler company 451 north cannon avenue, lansdale, pennsylvania 19446 tel: (215) 362-0700 / fax: (215) 362-5385 / www.centralsprinkler.com fire protection technical advance central technical advance 9-00 new and revised technical literature enclosed you will find literature for our new and revised products. please remove the old... central sprinkler company 451 north... 9-00 #1 tab - standard spray sprinklers 1... with pressure regulator 5-00 12-3.0 model du-2 amd with pressure switch...

Recall of fire protection system sprinklers

Date: august 8, 2001 dsl-bqa-01-034 to: nursing homes nh 19 facilities for the developmentally disabled fdd 13 hospitals hosp 14 hospices hspce 12 end stage renal dialysis units esrd 04 ambulatory surgical centers asc 05 adult family homes afh 12 community based residential facilities cbrf 15 residential care apartment complexes rcac 13 from: jan... The model designation and date may also be stamped on the frame or deflector.... affected models central "wet" sprinklers (manufactured from...

model g4a-300 quick response concealed automatic 300 psi (20,7 bar ...

The g4a-300concealer a quick response concealed sprinkler with 1 2(13mm) or 1½ (38mm) adjustment features 1. cover plate assembly attachment with½(13mm) adjustment. does not require clips or springs. 2. smooth aesthetic ceiling profile. 3. factory installed protective cap. 4. available in brass, chrome or black plated and white painted finishes. ... new york 10523 model g4a-300 quick response concealed automatic... a stock of spar e sprinklers should be maintained to allow quick replacement of...

central technical data book technical data book update, february ...

central technical data book technical data book update, february, 2002 updating instructions technical services: tel: (800) 381-9312/fax: (800) 791-5500 remove insert notes replace the table of contents dated 5-01 with the revised table of contents dated february 2002. use the new table of contents as a guide whe n inserting the referenced new... central technical data book technical data book update... the seriesrfii concealed pendent sprinklers area redesignationfor the model bv4 and bv4-fr....

Check your buildings for potentially faulty omega sprinkler heads

110 south union street ï alexandria, va 22314 ï 703ñ683ñ5880 ï 800ñ627ñ3136 ï fax 703ñ549ñ1114 v alue news of c heck y our b uildings f or p otentially f aulty o mega s prinkler h eads morgan & cheves, inc., would like to call your attention to potentially faulty fire sprinklers that could be in your buildings. omega model... Omega model sprinklers manufactured between 1983 and 1996 by central... omega model sprinklers are stamped or inscribed with the name central, the omega model...

sprinkler heads & accessories commercial sprinklers

... bulb type. the lf2 has been designed to operate with a particular temperature rating and heat responsive thermal characteristic, as well as to discharge water in a specific pattern and quantity per square foot relationship. the combination of the performance characteristics which are associated with the lf2 sprinklers have been proven to help... Residential sprinklers model lf2 residential pendent the 4.9 k-factor. model lf2 residential pendent and recessed pendent sprinklers are automatic sprinklers...

"o"-ring sealed sprinklers

Issued: april 2002 revised: november 2009"o"-ring sealed sprinklers introduction in ul news releases, ul recommended the immediate inspection and sample testing of all systems incorporating fire sprinklers equipped with an o-ring water seal. to assist property owners, authorities having jurisdiction and others in identifying "o"-ring sealed... Please note that these lists do not include sprinklers covered under replacement programs administered by central... r3831 spraysafe automatic sprinklers, ltd. model...

Technical data

Technical data february 15, 2008 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services: 877-384-5464 fax: 269-818-1680 email: techsvcs{*et*}vikingcorp. com model c-1 window sprinklers 1. description viking model c-1 window sprinklers are non-automatic, open, "outside" sprinklers intended for... The use of model c-1 window sprinklers may be limited due to occupancy and hazard. refer to the authority having jurisdiction prior to installation.

sprinkler wrenches

Sprinkler wrenches and cabinets technical data september 30, 2011 the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 t echnical services: 877-384-5464 fax: 269-818-1680 email: techsvcs[+at+]vikingcorp. com 1. description a. sprinkler cabinets viking sprinkler cabinets are metal enclosures constructed to... Determine appropriate cabinet from table 1 on this page for use with the specific model/number of sprinklers to be contained in the cabinet. 2.

Wet system manual

Wet system technical manual for operation, maintenance, and troubleshooting october, 2008 form no. f_010508 page ii technical data the viking corporation, 210 n industrial park drive, hastings mi 49058 telephone: 269-945-9501 technical services 877-384-5464 fax: 269-818-1680 email: techsvcs<;;at;;>vik ingcorp.com A. model j-1 alarm check valve 9... use of dry sprinklers in wet systems 32... notify local security guards and/or central alarm

Window sprinklers model ws

Fax 989-846-9231 www.globesprinkler.com printed u.s.a. 4077 airpark drive, standish, michigan 48658 989-846-4583 1-800-248-0278 june 2002 bulletin ws, rev. #3 m odel ws w indow s prinklers globe® product warranty globe agrees to repair or replace any of its own manufactured products found to be defective in mater ial or workmanship for a... Globe's model ws window sprinklers may be installed in various positions... o rdering i nformation specify quantity model number finish orifice...

Standard coverage

... pa 19446 215-362-0700 • fax 215-362-5385 www.tyco-fire.com printed usa / tfbp-chart / 5m / ul / 12-05 central, gem, star, aquamist... model (1) sprink.

Recalled sprinkler heads

To: ohio health care facilities from: bureau of regulatory compliance ohio department of health subject: recalled sprinkler heads date : march 13, 2002 the federal centers for medicare and medicaid services requested that we mail this notice to certified providers that are subject to the life safety code. central sprinkler co., an... central sprinkler co.... in particular buildings." the replacements will be phased in according to priority determined by the age of the sprinklers...

Top Queries


Recent Searches

 
DOC-TXT