Aci 117 PDF results

117-90 standard specifications for tolerances for concrete ...

Standard specifications for tolerances for concrete construction and materials (aci 117-90) 117-90 standard specifications for tolerances for concrete construction and materials standard specifications for tolerances for concrete construction... Standard specifications for tolerances for concrete construction and materials (aci 117-90) 117-90 standard specifications for tolerances for concrete construction...

Specification for tolerances for concrete construction and ...

american concrete institute® advancing concrete knowledge specification for tolerances for concrete construction and materials and commentary first printing june 2010 isbn 978-0-87031-379-0 copyright by the american concrete institute, farmington... aci 117-10 specification for tolerances for concrete construction and materials (aci 117-10) and commentary an aci standard reported by aci committee 117

Errata as of january 29th, 2008 aci 117/117r-90 standard ...

Through 16 th printings reported by aci committee 117 the following corrections should be made in all printings of aci 117r-90: figure 4.3, 4.4, and 4.5.3(c): in the far right figure, the bottom of the slab should be 99'-11 1/2" (100'-0 3/4"-11 3/4 Page 1 of 2 errata as of january 29 th, 2008 aci 117/117r-90 standard specifications for tolerance for concrete construction and materials (117-90) and...

Tolerances for suspended concrete slabs

Concrete floors are often placed on a suspended structural system consisting of a metal deck supported by open-web steel joists, steel beams, or precast concrete members. tolerances for the floors placed on these suspended systems are often misund erstood. aci 117-90, "standard specifications for tolerances for concrete construction and aci 117-90 requires no level alignment tolerance for the concrete because levelness depends on the locat ion and placement of the supporting structure and, after the...

F-numbers compared to "gap under the straightedge"

F-numbers compared to "gap under the straightedge" the table on the next page provides some approximations for comparison purposes between the f f(flatness) number system and the "gap under the straightedge" system. it should be noted that any comparison of "gap under the straightedge" numbers with f-numbers can only be an approximation, because of... The above is a direct quote from aci 117. • the last bullet points out that the "gap under the straightedge" method does not measure "levelness" at all, so there is no...

Slab thickness tolerances

Construction and materials." this document allows the same thickness tolerance-+3/8 in.(+10 mm) and -1/4 in. (-6 mm) -for both slabs on ground and elevated slabs 12 in. (300 mm) thick or less. these tolerances give owners, engineers, and... M ost project specifications, including aci 301-99, "specifications for structural concrete," reference aci 117-90, "standard specifications for tolerances for...

Replace failed boiler 660-11-112 june 1, 2011 revision 1 section ...

Replace failed boiler 660-11-112 june 1, 2011 revision 1 03 30 53 - 1 section 03 30 53 cast-in-place concrete part 1 - general 1.1 description: a. this section specifies cast-in-place structural concrete and material and mixes for other concrete. 1.2 tolerances: a. aci 117. B. slab finishes: aci 117, f-number method in accordance with astm e1155. 1.3 regulatory requirements: a. aci sp-66 aci detailing manual b. aci 318...

Summary report

co-sponsors american architectural manufacturers association american concrete institute american institute of steel construction american society of civil engineers construction institute concrete reinforcing steel institute floor covering installation contractors association portland cement association post-tensioning institute strategic... • wall finish - painting/coating/plaster aci 117-90 requires the relative alignment for a concrete wall to 3/8 in. in 10 ft or better. plaster specifications reference astm...

Section 03 30 53, miscellaneous cast-in-place concrete

Section 03 30 53 cast-in-place concrete part 1 - general 1.1 description: this section specifies cast-in-place structural concrete and material and mixes for other concrete. 1.2 related work: a. materials testing and inspection during construction: section 01 45 29, testing laboratory services. 1.3 tolerances: a. formwork: aci 117, except the... Publications are referenced in text by basic designation only. b. american concrete institute (aci): 117-06…tolerances for concrete construction and...

aci 301 specifications for structural concrete

Requirements with respect to the submittal of existing field- test data in support of mix-design submittals aci 301 specifications for structural concrete requirements with respect to the submittal of existing field- test data in support of mix-design submittals in order to meet a project's specific performance and design requirements, aci... aci 301 specifications for structural concrete requirements with respect to the submittal of existing field-test data in support of mix-design submittals in order to...

Section 03300 - cast-in-place concrete

Emery county senior center - green river 06/07 cast-in-place concrete 033000 - 1 section 033000 - cast-in-place concrete part 1 - general 1.1 related sections a. 014000 quality requirements b. 312000 earth moving. 1.2 section requirements a. submittals: product data. b. ready-mixed... Comply with astm c 94; aci 301, "specification for structural concrete"; aci 117, "specifications for tolerances for concrete construction and materials"; and crsi's...

Rebar inspection

Contractors should understand the process of rebar inspection, whether the inspection is done by their own forces or by an inspector re p resenting the owner or building o fficial. the goal of inspection or q u a l i t y - c o n t rol programs is to ensure that contract documents and building codes are followed. the programs also ensure structural... The engineer or a rchitect usually specifies the stand a rd tolerances to be followed, normally by re f e rence to aci 117. the inspector will establish a range of ac-c...

Anchor bolt tolerances

138 february 2004 / concrete international american society of concrete contractors 2025 s. brentwood blvd., suite 105 st. louis, mo 63144 phone: (314) 962-0210; fax: (314) 968-4367 website: www.ascconline.org; e-mail: ascc{.@.}ascconline. org american society of concrete contractors position statement #14 t this position statement from the american... The dispute arises from differing tolerances for anchor bolt placement given by the concrete industry in aci 117-90, "standard specifications for tolerances for...

Avoiding tolerance traps

What is a tolerance? permitted variation from a specified dimension or location "nono building is ever plumb, level, straight, building is ever plumb, level, straight, and true to dimension - that is, not exactly." john r. nichols, 1940 the best is the enemy of the good ‐‐‐ Each section of the proposed document and comments relating to changing a tolerance. • aci 117 can request backup data to support

Nebraska chapter library

Nebraska chapter library aci library contents - omaha 4315 cuming street omaha, ne 68131 librarian - ben ricceri (402) 556-3600 category i 2002 aci manual of concrete practice part 1 materials and general properties of concrete part 2 construction practices and inspection of pavements part 3 uses of concrete in buildings-design, specifications and... ... concrete slabs on grade scm-25 (92) corrosion of metals in concrete aci 22r-89 cement & concrete terminology aci 116r-90 standard tolerances for concrete construction aci 117...

Concrete masonry infill & stucco exterior with concrete frame ...

Here's the situation: many high-rise buildings(8 to 25 stories) are constructed with cast in place concrete frames and concrete block infill walls. typically the building plans call for the concrete columns and concrete slabs to be flush to the outside of the building. aportland cement- based plaster (stucco) is the most commonly specified finish. Repair methods and materials can be found in aci 546r concrete repair guide. reference 1: aci 117 "standard specifications for tolerances for concrete...

Significant changes in the 2002 acicode

S. k. ghosh, ph.d. president s. k. ghosh associates, inc. northbrook, illinois the author summarizes the significant changes made since the publication of the 1999 aci318 building code that are reflected in the 2002 edition of the code, which is expected to be released early in 2002. in addition to changes impacting conventionally reinforced... Section 7.5.2.2, tolerance at ends of members - the aim is to resolve a conflict in a tolerance value between aci 318 and aci 117. section 7.5.2.2 requires a ± 1 / 2 in...

Performance evaluation of residential concrete foundations

Dr. bijan 0. aalami, editor for professionals engaged in post-tensioning design issue 9 • july 2000 performance evaluation of residential concrete foundations by kenneth b.bondy 1 introduction many contemporary construction defect lawsuits involve light wood-framed residential buildings supported on post-tensioned concrete foundations built on... Equation (2) can be rearranged as follows: equation (3) substituting the aci 117-90 criteria of 10 for the minimum local f l number for conventional levelness quality...

Significant changes in the 2002 aci code - including changes ...

significant changes in the 2002 aci code - including changes affecting precast/prestressed concrete by s.k. ghosh, ph. d. president s.k. ghosh asociates inc. northbrook, il the author summarizes the significant changes made since the publication of the 1999 aci 318 building code that are reflected in the 2002 edition of the code, which is... (9) section 7.5.2.2, tolerance at ends of members - the aim is to resolve a conflict in a tolerance value between aci 318 and aci 117. section 7.5.2.2 requires a + ½ in...