4160v ct PDF results

Sizing a motor ct - weschler instruments

Voltage 115v 200v 230v 460v 575v 2300v 4160v horsepower 0.50 4 2.3 2 1 0.8 0.75 5.6 3.2 2.8 1.4 1... measure distance from the current transformer to the...

Measure 4160v service using powersight

Measure 4160v service using powersight page 1... to the actual voltage of the 4160v line. the ratio between the primary (the line) value and the secondary (the ct...

Oem instrument transformer reference guide_aug 2007

... db 126-127 2400 to 144005 kv & 15 kv cpt-ik-10, cpt-ik-15 1vap600002-db 128-131 circuit breaker application guide 132-133 cross reference 134-135 standard current transformer...

Differential protection of 3 phase induction motors

ct errors during short circuit : the ct's may have almost equal ratio as normal currents. but during short circuit conditions, the primary currents are unduly large.

Medium voltage catalog

ct series terminations are designed with a non-tracking outer insulating material that offers resistance to uv degradation and a self-cleaning outer surface that prevents...

Vacclad-w type vcp-w 5 and 15 kv, 36-inch-wide switchgear components

A each pole can accommodate up to two standard-accuracy cts or one high-accuracy ct. notee:(mr) = multi-ratio transformers. table 9. type abb byz zero sequence ct

Power plant electrical distribution systems

A 1 is for 6.9kv, a 2 is for 4160v, and a 3 is for 480v. the second character... glossary of terms ct - current transformer - an instrument transformer that...

Meter specification manual

4.06.15 3ph 4w socket ct (120/208v, 277/480v, 2400/4160v, or 7960/13,800v) 4.06.16* 3ph 4w "a"-base ct (120/208v, 277/480v, 2400/4160v, or

Section 16300 medium voltage equipment

ct range shall be selected appropriately for the load and shall not exceed the load by more than 50%. c. provide ct shorting block and/or test switches.

Planners

Sidewalk existing 4160v switchboard swbd1 concrete sidewalk 1 ex sub-panel 8a... tower ct-3 ex roof hatch m s m s m s etr etr etr etr 2 remove ex light fixture and...

Chapter 4 protective devices coordination

(c) existing protection including relay device numbers and settings, ct ratios, and time-current characteristic curves. (d) generator ratings and impedance data.

Pole-top primary metering installation, cluster mounted (12 or 21 ...

Oh: meters rev. #01: 04-15-10 058779 page 1 of 7 electric metering 058779 function: asset type: approved by: date: quoc hoang (qxh1) 04-15-10 rev. # 01:...

Tripping with the speed of light: arc flash protection

Install dedicated arc flash protection (+) very fast (0.15 cycles) (+) fairly inexpensive to implement (+) immune to ct saturation (+) supports arc flash breaker failure...

Sulation and

I nsulate s eal p rote ct 3 cesk s eri es e lbow g rounding /s ealing k its cesk elbow sealing kit for sealing and reinforcing load-break and dead-break elbows on...

Metal-enclosed capacitor banks medium voltage class, 5kv - 38kv

The user has only to set it in place, connect the incoming power and control cables and adjust the protective relays and control devices, control voltage and ct signal...

Contents by chapter

4.06.16* 3ph 4w "a"-base (120/208v, 277/480v, 2400/4160v, or 7960/13,800v) kw, kva 4.06.17 3ph 4w socket ct (120/208v, 277/480v, 2400/4160v, or 7960/13,800v)

Electrical design standard symbols

... transformer with two windings 06-10-05 variable voltage transformer 06-09-06 auto-transformer 06-09-08 choke / reactor 06-09-01b voltage transformer 06-09-10 current transformer...

Va-244-09-ib-0370 0002 ep101.pdf

... euh-1' m m m new chiller oil pump for chiller 31-ccu-1 480v-3ø-2 hp new chiller 31-ccu-2 4160v... secure unit to floor via unistrut assembly up to cooling tower 31-ct...

Compact, compartmentalized and reliable. hvl/cc medium voltage ...

ct (3) ct (3) door m m door m m m m door m door m m m door door fuse fuse fuse fuse vt (3) la 12 kv la 12 kv door m m m bft bft to transformer